Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
J. health med. sci. (Print) ; 7(4): 215-221, oct.-dic. 2021.
Article in Spanish | LILACS | ID: biblio-1396092

ABSTRACT

El objetivo del presente artículo ha sido describir el programa "Optimización de la Protección en Radiología Intervencionista Pediátrica en América Latina y el Caribe" (OPRIPALC) que nace el año 2018 como respuesta conjunta de la Organización Panamericana de la Salud y la Organización Mundial de la Salud, en cooperación con el Organismo Internacional de Energía Atómica, para colaborar con sus Estados miembros en asegurar que las exposiciones a la radiación de los pacientes pediátricos sean las mínimas necesarias durante los procedimientos intervencionistas. Actualmente, hay 18 centros de los siguientes 10 países que participan: Argentina, Brasil, Chile, Colombia, Costa Rica, Cuba, Ecuador, México, Perú y Uruguay. Para el desarrollo del programa se plantean una serie de objetivos, productos, actividades y resultados esperados. La puesta en marcha de la WEB de OPRIPALC ha significado un instrumento muy válido para seguir la información actualizada del programa. Un programa actualizado de formación en radioprotección para los profesionales implicados en el programa, se está realizando por medio de "webinars". Se deberá seguir actuando en la aplicación del programa de control de calidad básico para los equipos de rayos X participantes y validar los valores de los Niveles de Referencia para Diagnóstico (NRDs). Se propone formar un equipo de trabajo entre los Físicos Médicos y Tecnólogos Médicos participantes de OPRIPALC para implicarse en las pruebas de control básicas que todos los centros debieran realizar. Se han presentado algunos resultados iniciales de OPRIPALC en eventos científicos internacionales. Se está avanzando en proponer unos primeros valores sobre NRDs en procedimientos de intervencionismo cardiológico pediátrico por bandas de edad y peso. OPRIPALC es una de las pocas iniciativas de carácter regional para obtener valores de NRDs en procedimientos intervencionistas pediátricos. Se espera que tanto los valores de referencia como la metodología empleada en OPRIPALC, puedan ser utilizados en otras regiones del mundo.


The objective of this article has been to describe the program "Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean" (OPRIPALC) that was born in 2018 as a joint response of the Pan American Health Organization and the World Organization of the Health, in cooperation with the International Atomic Energy Agency, to collaborate with its member states in ensuring that radiation exposures of pediatric patients are the minimum necessary during interventional procedures. Currently, there are 18 centers from the following 10 countries participating: Argentina, Brazil, Chile, Colombia, Costa Rica, Cuba, Ecuador, Mexico, Peru and Uruguay. For the development of the program, a series of objectives, products, activities and expected results are proposed. The launch of the OPRIPALC WEBSITE has been a very valid instrument for following up-to-date information on the program. An updated training program in radiation protection for the professionals involved in the program is being carried out through webinars. It should continue acting in the application of the basic quality control program for the participating X-ray equipment and validate the values of the Diagnostic Reference Levels (DRLs). It is proposed to form a work team among the OPRIPALC participating medical physicists to get involved in the basic control tests that all centers should carry out. Some initial results of OPRIPALC have been presented at international scientific events. Progress is being made in proposing first values on DRLs in pediatric cardiac intervention procedures by age and weight bands. OPRIPALC is one of the few regional initiatives to obtain DRLs values in pediatric interventional procedures. It is expected that both the reference values and the methodology used in OPRIPALC can be used in other regions of the world.


Subject(s)
Humans , Child , Pediatrics/standards , Radiation Protection/standards , Cardiology/standards , Quality Control , Reference Standards , Reference Values , Safety , Radiology, Interventional , Caribbean Region , Diagnostic Techniques, Cardiovascular , Process Optimization , Diagnostic Reference Levels , Latin America
2.
Electron. j. biotechnol ; 30: 103-109, nov. 2017. ilus, tab, graf
Article in English | LILACS | ID: biblio-1021917

ABSTRACT

Background: Small ribonucleic acids represent an important repertoire of mobile molecules that exert key roles in several cell processes including antiviral defense. Small RNA based repertoire includes both small interfering RNA (siRNA) and microRNA (miRNA) molecules. In the Prunus genus, sharka disease, caused by the Plum pox virus (PPV), first occurred on European plum (Prunus domestica) and then spread over among all species in this genus and thus classified as quarantine pathogen. Next-generation sequencing (NGS) was used for the study of siRNA/miRNA molecules; however, NGS relies on adequate extraction protocols. Currently, knowledge of PPV-Prunus interactions in terms of siRNA populations and miRNA species is still scarce, and siRNA/miRNA extraction protocols are limited to species such as peach, almond, and sweet cherry. Results: We describe a reliable procedure for siRNA/miRNA purification from Prunus salicina trees, in which previously used protocols did not allow adequate purification. The procedure was based on a combination of commercially available RNA purification kits and specific steps that yielded high quality purifications. The resulting molecules were adequate for library construction and NGS, leading to the development of a pipeline for analysis of both siRNAs and miRNAs in the PPV­P. salicina interactions. Results showed that PPV infection led to altered siRNA profiles in Japanese plum as characterized by decreased 24-nt and increased 21- and 22-nt siRNAs. Infections showed miR164 and miR160 generation and increased miR166, miR171, miR168, miR319, miR157, and miR159. Conclusion: We propose this protocol as a reliable and reproducible small RNA isolation procedure for P. salicina and other Prunus species.


Subject(s)
RNA, Plant/isolation & purification , MicroRNAs/isolation & purification , RNA, Small Interfering/isolation & purification , Prunus domestica/genetics , Plant Diseases/virology , Plum Pox Virus/physiology , Host-Pathogen Interactions , High-Throughput Nucleotide Sequencing , Real-Time Polymerase Chain Reaction , Prunus domestica/immunology , Prunus domestica/virology
3.
Rev. panam. salud pública ; 20(2/3): 113-124, ago.-sept. 2006. tab
Article in Spanish | LILACS | ID: lil-441026

ABSTRACT

OBJETIVO: Determinar la correlación entre ciertos indicadores de calidad para los servicios de imaginología y la certeza en la interpretación de los exámenes radiológicos para cuatro quejas frecuentes: las masas de la mama, el malestar del aparato digestivo, el dolor de espalda y los síntomas de la tuberculosis. MÉTODOS: Se evaluaron veintiséis servicios de radiología en Argentina, Bolivia, Colombia, Cuba y México. Se evaluaron los equipos de mamografía y de radiografía/fluoroscopia convencional usados en los servicios seleccionados utilizando protocolos comunes, hojas de especificaciones técnicas, instrumen-tos de prueba, maniquíes y sistemas de dosimetría calibrados. Los estudios se realizaron en establecimientos de complejidad media. Se obtuvo el consentimiento informado de todos los pacientes estudiados, y se garantizó la confidencialidad de los resultados. Se evaluaron y documentaron los siguientes parámetros: el tipo de establecimiento (público o privado); la población cubierta; el número de pacientes y exámenes; los equipos radiológicos, los de procesamiento de imágenes y los suministros; la educación y la capacitación del personal profesional y técnico; los programas de la garantía de la calidad y del mantenimiento preventivo, y la adherencia a las normas de seguridad radiológica. Se determinaron el funcionamiento de los equipos de rayos X, los receptores de la imagen y las procesadoras; las condiciones del cuarto oscuro y de la visualización de las imágenes; las dosis recibidas por los pacientes y la calidad de la imagen, usando parámetros uniformados en todos los casos. Los paneles independientes de radiólogos, reconocidos como expertos por la sociedad radiológica local, evaluaron la calidad de las imágenes clínicas obtenidas y realizaron una interpretación radiológica para cada paciente usando las mismas películas e historia clínica a disposición de los médicos especialistas en imaginología de la institución. El acuerdo entre...


OBJECTIVE: To determine the correlation between certain quality indicators for imaging services and the accurate interpretation of radiological exams for four frequent complaints: breast lumps, gastrointestinal discomfort, back pain, and symptoms of tuberculosis. METHODS: Twenty-six radiology services in Argentina, Bolivia, Colombia, Cuba, and Mexico were assessed. The mammography and conventional radiographic/fluoroscopic equipment used in selected services were evaluated utilizing common protocols, data sheets, testing instruments, phantoms, and calibrated dosimetry systems. The studies were performed in medium-complexity facilities. Informed consent was obtained from all patients studied, and the confidentiality of results was guaranteed. The following parameters were documented: type of facility (public vs. private); population covered; patient workload; radiological and image-processing equipment and supplies; education and training of professional and technical staff; quality assurance and preventive maintenance programs, and adherence to radiation safety standards. The performance of x-ray units, image receptors and processors; darkroom and image viewing conditions; patient doses and image quality, were determined using standardized parameters in all cases. Independent panels of radiologists, recognized as experts by the local radiological society, assessed the quality of the clinical images obtained and performed a radiological interpretation for each patient using the same films and clinical history available to the institution's imaging physicians. The agreement between the panel of expert's reports and those of local radiologists was taken as an indicator of the radiological diagnostic accuracy. RESULTS: Analyses were carried out of 366 mammograms, 343 radiological procedures for gastrointestinal complaints, 319 X-rays of the spinal column, and 157 chest radiographs. The agreement between the radiological interpretation of...


Subject(s)
Humans , Radiology/standards , Latin America , Quality Assurance, Health Care , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL